Thursday, June 4, 2015

Note separator installation:

1. Install a vertical gap of vertical focus is adjusted, the level of the turntable and turntable with two heads between the wheel and the two heads arc axis should coincide.
2. Install the precision requirements: the centerline deviation limit the device to ± 3mm, elevation limit deviation of ± 5mm; rows mounted recycling cross belt magnetic separator, centerline straightness tolerance of 3mm, relative elevation difference of no more than 3mm.
3. After installation ensure that machinery does not come loose, the line does not appear to detect leakage short circuit and so on.
 